{"id":160,"date":"2021-04-28T17:04:58","date_gmt":"2021-04-28T14:04:58","guid":{"rendered":"https:\/\/ecofloor-bg.com\/en\/?post_type=product&#038;p=160"},"modified":"2022-01-04T17:08:00","modified_gmt":"2022-01-04T15:08:00","slug":"psv-15-w-m","status":"publish","type":"product","link":"https:\/\/ecofloor-bg.com\/en\/products\/underfloor-heating\/underfloor-heating-with-heating-cables\/psv-15-w-m\/","title":{"rendered":"Heating cable PSV 15 W\/m"},"content":{"rendered":"<p>Heating cable for underfloor heating under tiles with a power of 15 W \/ m. The cable is single-wire, with a diameter of 4.5 &#8211; 4.8 mm, and an additional 5 m. power cords at both ends. It has high mechanical resistance, and its full protective screen allows it to be placed in wet rooms. Underfloor heating with a heating cable provides great freedom in the construction of the system, as the manual laying of the cable allows an individual approach to moving and non-standard rooms, as well as easy bypassing of fixed furniture.<\/p>\n<h2>Product range<\/h2>\n<table class=\"has-fixed-layout table\">\n<thead>\n<tr>\n<th class=\"has-text-align-center\" data-align=\"center\">Product<\/th>\n<th class=\"has-text-align-center\" data-align=\"center\">Output [W]<\/th>\n<th class=\"has-text-align-center\" data-align=\"center\">Length [m]<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15200<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">200<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">13.7<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15340<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">340<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">22.2<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15420<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">420<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">28.1<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15550<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">550<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">36.7<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15660<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">660<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">44.7<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15800<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">800<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">52.3<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15880<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">880<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">58.6<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 15960<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">960<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">64.1<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 151070<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">1070<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">71.5<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 151210<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">1210<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">81.0<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 151300<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">1300<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">84.1<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 151580<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">1580<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">104.6<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 151900<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">1900<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">128.6<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 152200<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">2200<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">150.3<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 152800<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">2800<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">189.4<\/td>\n<\/tr>\n<tr>\n<td class=\"has-text-align-center\" data-align=\"center\">PSV 153400<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">3400<\/td>\n<td class=\"has-text-align-center\" data-align=\"center\">227.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Basic principles and requirements<\/h2>\n<ul>\n<li>A distance of at least 5 cm from peripheral walls must be provided<\/li>\n<li>The heating cable should not be laid under fixed furniture and massive objects &#8211; kitchen appliances, bathtubs, shower cabins, fixed toilets, etc.<\/li>\n<li>Minimum 6 cm thermal insulation and 3 cm screed or the specialized reinforced thermal insulation F-BOARD 6\/10 mm<\/li>\n<li>The heating cable cannot be cut or shortened.<\/li>\n<li>The heating cables must not get intertwined<\/li>\n<li>Cable coils should not be less than 5 cm apart<\/li>\n<li>The floor sensor of the thermostat of your choice is placed at an equal distance between the heating cables<\/li>\n<\/ul>\n<h2>Documentation<\/h2>\n<ul>\n<li><a href=\"https:\/\/ecofloor-bg.com\/wp-content\/uploads\/2020\/08\/PSV_instrukcii_BG2.pdf\">Installation manual for <strong>PSV<\/strong><\/a><\/li>\n<li><a href=\"https:\/\/ecofloor-bg.com\/wp-content\/uploads\/2020\/08\/PSV-certificate.pdf\">Certificate <strong>PSV<\/strong><\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Heating cable for underfloor heating under tiles.<\/p>\n<ul>\n<li>Heating cable with full protective screen for use in dry or wet rooms<\/li>\n<li>For new construction or floor repair<\/li>\n<li>Efficient, economical and safe<\/li>\n<\/ul>\n","protected":false},"featured_media":368,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[22,37],"product_tag":[],"class_list":{"0":"post-160","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-underfloor-heating","7":"product_cat-underfloor-heating-with-heating-cables","8":"sales-flash-overlay","9":"woocommerce-text-align-center","10":"woocommerce-image-align-center","11":"do-quantity-buttons","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/product\/160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/comments?post=160"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/media\/368"}],"wp:attachment":[{"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/media?parent=160"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/product_brand?post=160"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/product_cat?post=160"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ecofloor-bg.com\/en\/wp-json\/wp\/v2\/product_tag?post=160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}